Replacing Diesel Gensets with LiFePO4 at Telecom Base Stations
Typical requirement: a macro base station estate where grid supply is weak, intermittent or absent and diesel gensets carry the backup duty. Fuel logistics, fuel theft and genset maintenance dominate site operating cost, while severe weather can block access to sites for extended periods. Origin Drive Future configures rack-mount LiFePO4 backup modules with outdoor-rated enclosures, controller-native telemetry and genset-free operation for this class of site.
Illustrative application scenario, based on the requirements we quote for. It does not represent a named customer or a completed reference project.

Macro base station sites · Telecom backup power

What this site limits
- Backup hours are set per site category, not by one network-wide number
- Rack format has to fit the existing cabinet: height, depth and the DC bus voltage already in use
- Cabinet temperature sets the capacity derating and the warranty statement
- Alarms must reach the existing monitoring platform
- Remote sites mean the routine maintenance interval is measured in months
The challenge
Our solution



What this configuration supports
Design at a glance
The question site owners raise first is rarely about fuel cost — it is whether a truck has to be sent to a remote site at all. Remote telemetry should flag a degrading unit before the site goes off air.
— Origin Drive Future, telecom backup application engineering
How the order is executed
The terms below apply to the batteries and hardware in this configuration. Voltage, capacity, quantity and destination are written into the quotation, and the items below are confirmed in writing before production.
| Minimum order | 20 units per model for a production order. Single units are available as paid evaluation samples, credited against your first production order. |
| Lead time | 25 days after the deposit is received for a standard batch. Tooling, custom BMS or project-specific capacity is scheduled separately and confirmed on the quotation. |
| Payment | T/T: 30% deposit with the order, balance against the bill of lading copy. |
| Shipment | Tell us the destination port or door. The quotation states the Incoterm and the freight option we are quoting, so the delivered cost is comparable across suppliers. |
| Packing | Packed to the packing instruction applying to UN3480 or UN3481, terminals protected, lithium battery mark and hazard label applied, pallets strapped and shrink-wrapped. |
| Documents with the goods | Packing list, commercial invoice, MSDS, UN38.3 test summary and report, shipper’s declaration for dangerous goods, and the bill of lading or air waybill. |
| Per unit | Datasheet for your model and the end-of-line test record for that serial number. |
| Warranty | 3–5 years, depending on model, written into the contract. |
| HS classification | Lithium-ion accumulators, heading 8507.60. The national tariff line and duty rate are confirmed against your destination before the order is placed. |
Documents: Packing and shipping document checklist · provided with your quotation · BMS protocol mapping note · provided with your quotation
How to verify before ordering
- Per-site-category runtime table showing the load list it is based on
- Evaluation module with its factory inspection record
- Interface note for the existing rectifier and monitoring platform
- UN38.3 test summary report and transport documents
- Written confirmation of BMS alarm points, communication protocol and warranty
Models that fit this scenario
Every figure in these tables is published on the matching product page. Voltage, capacity, enclosure and connector can be re-rated for your project.
Commercial & Industrial Energy Storage
| Application / load | Voltage platform & capacity | Current & thermal design | BMS & communication |
|---|---|---|---|
| Factories, telecom sites and commercial buildings on peak shaving and demand charge management | 100 kWh / 50 kW cabinet · battery-only DC cabinet, 51.2 V DC bus (16S), paired with an external 50 kW PCS or DC-coupled PV inverter | 0.5C continuous charge and discharge; forced-air cooling; IP54; DC round-trip efficiency 88%-90% | Three-level BMU / BCU / BAU protection with aerosol fire suppression; CAN / RS485 / Ethernet (Modbus TCP for EMS and SCADA) |
| Industrial parks and mini-grids with a 10-foot footprint | 215 kWh liquid-cooled container · 768 V DC bus (240S), 100 kW | 0.5C continuous; liquid cooling holding cell temperature difference below 3 °C; IP54; 89%-91% | Perfluorohexanone or aerosol suppression with gas, smoke and temperature detection; CAN / RS485 / Ethernet, IEC 61850 optional |
| Large parks and grid-side projects needing battery and PCS in one enclosure | 500 kWh / 250 kW container · 1331.2 V DC bus (416S), 250 kW PCS and EMS integrated in a 20-foot container | 0.5C continuous; liquid cooling with redundant circulation pumps; IP54; 89%-91% | Grid-tied, off-grid or diesel generator support; CAN / RS485 / Ethernet, IEC 61850 optional; explosion-proof pressure relief |
Have a similar project?
Tell us your site, load and volume and we will come back with a configuration and price.
