LiFePO4 Backup Storage for Homes on Unstable Grids
On a weak distribution grid, power does not fail once a season. It fails in short, repeated interruptions, usually at the worst time of day, with voltage sag that trips air conditioners and restarts inverters. Rooftop PV alone cannot cover this, because without storage the system shuts down the moment the grid drops. This configuration pairs a low-voltage lithium storage unit with a hybrid inverter so a household keeps its cooling and lighting through an interruption, and so an installer can wire, commission and service every home the same way.
Illustrative application scenario, based on the requirements we quote for. It does not represent a named customer or a completed reference project.

Residential energy storage · Low-voltage platform

What this site limits
- Required backup hours per outage set the pack energy, not the daily household consumption
- Where the enclosure is placed decides the ingress protection and the ventilation path
- Charging from an unstable grid requires wide input tolerance and no grid back-feed
- Household circuits are divided into backed-up and non-backed-up loads before installation
- Maintenance has to be possible without opening cells, ideally without a site visit
The challenge
Our solution



What this configuration supports
Configuration profile
We are not asked for a payback story. We are asked for the air conditioning to keep running when the grid drops, and that is what a quoted configuration has to guarantee.
— Common requirement from residential solar installers
How the order is executed
The terms below apply to the batteries and hardware in this configuration. Voltage, capacity, quantity and destination are written into the quotation, and the items below are confirmed in writing before production.
| Minimum order | 20 units per model for a production order. Single units are available as paid evaluation samples, credited against your first production order. |
| Lead time | 25 days after the deposit is received for a standard batch. Tooling, custom BMS or project-specific capacity is scheduled separately and confirmed on the quotation. |
| Payment | T/T: 30% deposit with the order, balance against the bill of lading copy. |
| Shipment | Tell us the destination port or door. The quotation states the Incoterm and the freight option we are quoting, so the delivered cost is comparable across suppliers. |
| Packing | Packed to the packing instruction applying to UN3480 or UN3481, terminals protected, lithium battery mark and hazard label applied, pallets strapped and shrink-wrapped. |
| Documents with the goods | Packing list, commercial invoice, MSDS, UN38.3 test summary and report, shipper’s declaration for dangerous goods, and the bill of lading or air waybill. |
| Per unit | Datasheet for your model and the end-of-line test record for that serial number. |
| Warranty | 3–5 years, depending on model, written into the contract. |
| HS classification | Lithium-ion accumulators, heading 8507.60. The national tariff line and duty rate are confirmed against your destination before the order is placed. |
Documents: Packing and shipping document checklist · provided with your quotation · BMS protocol mapping note · provided with your quotation
How to verify before ordering
- Sizing calculation showing outage duration, the critical load list and the reserve margin
- Evaluation unit with its factory inspection record
- BMS behaviour report: transfer time, alarm thresholds and recovery
- UN38.3 test summary report and MSDS
- Installation note covering circuit division and protection settings
Models that fit this scenario
Every figure in these tables is published on the matching product page. Voltage, capacity, enclosure and connector can be re-rated for your project.
Residential Energy Storage
| Application / load | Voltage platform & capacity | Current & thermal design | BMS & communication |
|---|---|---|---|
| Household daily use and solar self-consumption | 5.12 kWh wall-mounted battery · 51.2 V, 100 Ah (16S1P) | Maximum continuous charge current 50 A; IP20 wall cabinet; -20 °C to +60 °C | Cell voltage and temperature monitoring; CAN / RS485, Bluetooth optional, display or app, dry contacts for generator or load control |
| Homes and small shops needing two days of backup | 10.24 kWh stackable system · 51.2 V, 200 Ah (16S2P) | Charge current 100 A; IP20 stacked cabinet with inter-module connectors | Same BMS set as the 5.12 kWh unit; CAN / RS485, Bluetooth optional |
| Villas and larger homes with a hybrid inverter | 15 kWh rack-mounted ESS · 51.2 V, 300 Ah (16S3P) | Charge current 150 A; 19-inch cabinet with front service access, IP20 | Cell voltage and temperature monitoring; CAN / RS485, Ethernet and Wi-Fi optional |
Have a similar project?